Features you can set at the factory or in the field.
Learning Track · Module 2: Luminaires · Step 10 of 101
- Output current: set the exact light level for the road. One luminaire model can cover many roads.
- Stand-alone dimming profile: fixed steps, timed from switch-on.
- Virtual midnight: the driver learns the night length from past on and off times, finds the middle of the night, and dims around it.
- CLO: constant light output over the life.
- Thermal protection: current goes down if the LED module gets too hot.
- Auxiliary power: 24 V for a node or sensor in a Zhaga socket.
- D4i data: energy, burn hours, faults, and luminaire data. See DALI and D4i.
Note
Record the driver programme of each model in the asset register. Programme replacement drivers the same way.
Sources
- IEC 61347-2-13 Particular requirements for DC or AC supplied electronic control gear for LED modules
- IEC 62386-207 DALI: LED modules
- DALI Alliance D4i specifications
Changes: 30 October 2026: First publication: guides for Europe, the Middle East, South Asia, and the USA; failure library; tender clause library; comparisons; tools; downloads. See the changelog. Found a mistake? Report it.